Questions? 916-760-4524

3" DERINGER 50G (RPDA)

The 3" Deringer 50G Reduced Pressure Detector Assembly prevents non-health hazard pollutants and hazardous contaminants from entering a potable water supply system when backpressure and/or backsiphonage conditions occur. Used primarily on fire sprinkler systems when monitoring of unauthorized water use is required.

The smallest, lightest, most economical, best performing, and only all stainless steel backflow preventer. Period.

Approvals

Important Note: Install with FLEX Couplings or Flange Adapters Only. DO NOT use RIDGED Couplings!

MSRP:

$3,989.00

Pro Price:

$2,849.00
Write a review about this product ▶

NEVER install an RP or RPDA in a location where any amount of discharge from the Relief Valve will cause property damage. For an indoor, pit, vault, mechanical room or enclosure installation of an RP or RPDA, an auxiliary drain (separate and independent of the Air Gap Assembly) is REQUIRED and MUST be properly sized for the Maximum Relief Valve Discharge Rate (see specifications below) corresponding to the system/supply pressure. Backflow Direct shall not be responsible for any damage caused by lack of auxiliary drain, location of auxiliary drain or undersized auxiliary drain. If the buyer is unwilling to meet this requirement please DO NOT purchase this product.



NEVER install an RP or RPDA in a location where any amount of discharge from the Relief Valve will cause property damage. For an indoor, pit, vault, mechanical room or enclosure installation of an RP or RPDA, an auxiliary drain (separate and independent of the Air Gap Assembly) is REQUIRED and MUST be properly sized for the Maximum Relief Valve Discharge Rate (see specifications below) corresponding to the system/supply pressure. Backflow Direct shall not be responsible for any damage caused by lack of auxiliary drain, location of auxiliary drain or undersized auxiliary drain. If the buyer is unwilling to meet this requirement please DO NOT purchase this product.

Deringer Reduced Pressure Detector Assembly Backflow Preventer RPDA-II Title
Deringer Reduced Pressure Detector Assembly Backflow Preventer RPDA-II Cutaway

The Deringer 50G Reduced Pressure Detector Assemby prevents non-health hazard pollutants from entering a potable water supply system when backpressure and/or backsiphonage conditions occur. Used primarily on fire sprinkler systems when monitoring of unauthorized water use is required.

Deringer Reduced Pressure Detector Assembly Backflow Preventer RPDA-II Approvals
Maximum Working Pressure:
175psi (12.1 bar)
Temperature Range:
33° - 140°F (1° - 60°C)
End Connections
- IPS Groove for Steel Pipe:
AWWA C606
- Flange Adapters:
ANSI B16.1 Class 125
Lead Free:
0.25% Maximum by Weight

Micro type-II  Bypass TM Assembly

The type-II bypass assembly is a new technology to the backflow industry and is used on Backflow Direct's Deringer 50 (RPDA-II).

As more manufacturers begin to utilize this technology it is only a matter of time before it’s widely used and is more commonly seen than the old type-I bypass assembly.

We created this video to provide a clear explanation on how the type-II bypass provides the EXACT same level of protection as a type-I bypass as well as some of the similarities and differences between the two.

Flow Performance

Deringer Reduced Pressure Detector Assembly Backflow Preventer RPDA-II Flow Performance

Measures &  Materials

Deringer Reduced Pressure Detector Assembly Backflow Preventer RPDA-II Measures and Materials
Valve Housing:
304 Stainless Steel
Valve Cover:
304 Stainless Steel
SOV Disks:
EPDM/304SS:
SOV Shafts:
304 Stainless Steel
Bypass Spring:
302 Stainless Steel
RV Spring:
302 Stainless Steel
SOV Bearings:
Teflon/Bronze
Non Wetted Bolts:
Grade 8 Zinc Plated
Check Disks:
Silicone
Wetted Fasteners:
18-8 Stainless Steel
Bypass Components:
Lead Free Bronze
RV Housing:
304 Stainless Steel
Check Springs:
17-7 Stainless Steel
Check Pins:
17-7/18-8 Stainless Steel
Check Seats:
Noryl Polymer
O-Rings:
Buna-N
Bypass Internals:
ABS Polymer
RV Hose:
Braided Stainless Steel Wire

Engineering &  Specifications

The Deringer 50G(X) Reduce Pressure Detector (RPDA-II) Valve shall utilize two independent Dual Action Check modules contained within a single valve housing constructed of entirely of stainless steel. Dual Action Check modules shall operate as a “poppet style” check under low flow conditions, operate as a “swing style” check under high flow conditions and utilize replaceable silicone elastomer sealing discs. Valve assembly shall include two resiliently seated and inline serviceable AWWA C509 gate valves of type outside yoke and stem (OS&Y). Gate valves shall utilize a stainless steel stem with a pre-machined groove for installation of supervisory tamper switches. Assembly test cocks shall be handle-less and operate via a tamper resistant actuator. Assembly shall utilize a single full access service port and a cover with an “inline” replaceable elastomer seal. Relief valve shall operate without the use of sliding seals and shall be constructed entirely of stainless steel. The bypass assembly shall include a meter registering gallons or cubic feet, a single check valve and test cocks. Assembly shall be serviceable without the use of special tools.

 Maximum Relief Valve  Discharge Rates

Deringer RPDA-II Backflow Preventer Relief Vlave Discharge Rate

Air Gap Assembly will capture and evacuate light water discharge from the Relief Valve caused by daily fluctuation in system/supply pressure. An Air Gap Assembly will NOT capture and evacuate the Maximum Relief Valve Discharge Rate caused by catastrophic valve or system failure. An auxiliary drain (separate and independent of the Air Gap Assembly) is REQUIRED and MUST be properly sized for the Maximum Relief Valve Discharge Rate. Backflow Direct shall not be responsible for any special, consequential or incidental damages, including without limitation, repair costs, lost profits, property damage, or any other costs resulting from labor charges, delays, vandalism, negligence, fouling caused by foreign material, adverse water conditions or any other circumstances, caused by lack of auxiliary drain, location of auxiliary drain or undersized auxiliary drain.

Retrofit   Spool Program

The Backflow Direct Retrofit Program is the easiest spool ordering process in the industry!

Simply go to our online Retrofit Spool Form and submit a few pieces of needed information. Backflow Direct will take the information provided and create a CAD drawing of the completed retrofit package along with a quote for you to review.

When you are ready to order, simply confirm by email and BackFlow Direct will start your order. It really is THAT easy!

BackFlow Direct's retrofit program video provides an easy to understand demonstration of the ordering process from start to finish. Please feel free to contact us with any questions at [email protected]

TECHNOLOGY

Top

True-Seal™   Check Modules

The True Seal Check Valve was designed to incorporate a poppet only motion during the check stroke and is used exclusively on the first check assembly on the Deringer RP and RPDA models and Magnum RP model. This design allows a more consistent pressure loss across the check valve which helps maintain a steady and continual closure of the Relief Valve.

  • Light weight engineered polymer components
  • Modular for easy removal of complete check from body
  • Easily disconnect spring tension for safe check servicing
  • Replaceable Silicone Rubber Elastomer Disk
  • Excellent resistance to fouling.
Deringer & Magnum 40/50 First Check Skewed
Deringer & magnum 40/50 Low Flow Poppet Action

Poppet Action

Features:

  • 100% of check stroke is that of a poppet check
  • Consistent static sealing
  • Excellent resistant to fouling
  • Reliable check closure
  • Stable flow characteristics at ALL flow rates

Dual-Action™  Check Modules

The Patented Dual-Action Check™ (US8875733) is the core technology behind the superior performance of Deringer Backflow Prevention Product Line. The Dual-Action Check™ combines all of the best features of industry standard “poppet” checks and “swing” checks into a single high performance check module.

  • Light weight engineered polymer components.
  • Modular for easy removal of complete check from body.
  • Easily disconnect spring tension for safe check servicing.
  • Replaceable Silicone Rubber Elastomer Disk.
  • Excellent resistance to fouling
Deringer Dual Action Check Skewed View
Deringer Low Flow Poppet Action

Poppet Action

Features:

  • Initial 25% of check stroke is that of a poppet check.
  • Consistent static sealing
  • Excellent resistant to fouling
  • Reliable check closure
  • Stable flow characteristics at lower flow rates

Swing Action

Features:

  • Final 75% of check stroke is that of a swing check.
  • Minimal friction loss at high flow rates.
  • More linear flow path water through valve.
Deringer High Swing Action

Bow-Seal™  Full Access Cover

The Patented Bow-Seal™ Full Access Cover (US8844562) is pre-formed to cylindrical shape friendly to high fluid pressure. This allows the cover to be much thinner and lighter than traditional flat covers while still providing FULL and EASY access to Dual Action™ Check Modules.

Additional features include:

  • Light weight
  • Simple removal
  • No sliding seals
  • Full access to valve internals
  • No cumbersome and heavy couplings
Deringer Backflow Preventer Bow Seal Access Cover

Tamper Resistant  Test Cock

The Deringer tamper resistant ½” and ¾” ball valves are the first handle-less test cocks found on large diameter backflow devices in the industry. The top of the valve actuation stem has a unique shape that uses an independent custom wrench to open and close test cocks. All test cocks are lead free and meet the SDWA requirements.

Deringer Tamper Resistant Test Cocks

Micro-Bypass™  Assembly

The Deringer 30/50 Micro Bypass™ Assembly is a type II bypass that utilizes an angled check valve and includes a standard 5/8 X 3/4 water meter for water use detection. It is the shortest, lightest and smallest bypass in the industry and the same bypass is used on all size Deringer 30/50 models. Constructed of lead free bronze, the micro bypass assembly meets all SDWA lead free standards.

Deringer Mirco Bypass Assembly 2½ - 4

Bypass-Angled  Check Valve

The bypass angled check valve has many features shown in the graphic below that are fundamental to creating the shortest, lightest and smallest bypass in the industry.

Deringer Bypass Angled Check Valve Image

Relief  Valve

The Deringer 40/50 Relief Valve uses a stainless steel body, piston seal and stainless steel sensing line and has been designed to be the smallest and lightest Relief Valve in the industry. Unlike previous relief valve designs, the piston seal does not use the body of the relief valve to align itself properly when closing and opening and instead uses the guide pin on the piston. This will aid in making the Relief Valve resistant to build up and binding. All components of the relief valve are lead free and meet the SDWA requirements.

Relief Valve Image

DOWNLOADS

Top

Deringer Specification Sheets

The Deringer 50G Specification Sheet includes information on valve characteristics, flow performance data, approval status and engineering specifications for all sizes. This file can be downloaded as a PDF and saved for future use.

Download pdf button




Backflow Direct Product Warranty

Relief Valve Discharge Rates

This is a printable version of the relief valve discharge rates for Deringer and Magnum backflow preventors as well as information on the air gap assembly.

Download pdf button




RP Mianitenance Instructions

Maintenance   Instructions

The Deringer 40G/50G Maintenance Instructions provide step by step procedures for maintaining a 2½" - 4” Deringer 40G/50G backflow preventer. A printable PDF document and video of these instructions are both available.

Download pdf button




Backflow Direct Warranty

Product  Warranty

This printable document provides information for the Backflow Direct one year warranty for Deringer and Magnum backflow preventers.

Download pdf button View Video Button


WARNING: Cancer and Reproductive Harm - www.p65warnings.ca.gov     Copyright © 2018 BackFlowDirect LLC, All Rights Reserved.